RevitForum is a vibrant community for Revit users of all levels, and the best part? It's completely free to join and use! We keep the platform ad-free for signed-in members, to ensure a smooth and distraction-free experience. To help us keep RevitForum running strong and ad-free, consider making a small donation.
May 11, 2022 · Revit - Inconsistent Units and how to neutralize them. Round Function In Formulas - New in Revit 2012 Values in formulas can be now rounded up or down. For example, when riser height is calculated, one needs the function “round” to find the appropriate value. ROUND(x) The round function returns a number rounded nearest to a whole number. It ...
Posts:4564. Location:Boxtel, Netherlands. #8. August 23, 2013, 07:27 AM. You can also use the rotate tool, set the rotation point on the wall you need to align to, set the start angle horizontal and snap the end angle to the wall. Don't need to exactly "know" the angle up front or draw a refplane.
Sep 15, 2017 · RFO Benchmark v3.# (Updated for 2025) September 15, 2017, 02:04 PM. Updated 2024.09.16. The Revit 2025 benchmark is out, and is being called version 3.4, instead of version 3.3, because the test DOES have some minor differences in it. BUT, the numbers should all still be valid as a mostly apples to apples comparison. Here is a quick breakdown:
Location:Dubrovnik, Croatia. #1. Fixture Units. February 14, 2014, 01:34 PM. Hi guys I have a question regarding Fixture Units (FU) of Plumbing fixtures in Revit. In my country DIN norms are accepted, and by DIN norms the FU equals 0,25 l/s and it is a fixed value I can't find anywhere what is the number of FU in Revit or is it even possible ...
Feb 6, 2015 · This way, all you have to do is select the correct voltage and enter the desired nominal horsepower, and the correct FLA value will automatically populate. You can then take this FLA value and multiply it by the Voltage and, for 3 phase only, the square root of 3 (1.732) to get your Apparent Load in Volt-Amperes.
Posts:346. Location:KC,MO. #1. Room color fill regions not working!!!! July 29, 2014, 05:24 PM. This is driving me crazy, and everyone who knows anything about Revit in my office has looked at it and can't figure it out... For some reason, only certain rooms will show color and certain rooms won't, even though all of the parameters are the same.
Material Cutouts. September 21, 2012, 07:06 PM. Trying to make a 3/8" thick bent steel plate with a laser cut cutout pattern. It will be a balcony guardrail. When I apply my cutout pattern as a material it shows up separately on both sides of the panel. I have tried just painting the material with cutout to the outside face of the panel and ...
Section Head Color. January 20, 2011, 06:32 PM. Hello all, I would like to know if it is possible to change the color of 'linked' objects like sections heads and callout bubbles to be black, instead of blue. I know that this can be defined within the print settings. What I would like to know is if it is possible to change it in the model as well.
The problem is that the room info dose not come across from the linked model. :banghead: After creating your room schedule and you are on the fields tab, lower left there is a drop down menu where you can select links. typically though Revit MEP uses spaces (and subsequent scheduling). cant remember exact wording ATM but it's all there :wine ...