Yahoo Web Search

  1. justanswer.co.uk has been visited by 10K+ users in the past month

    Thousands of highly rated, verified Local Experts ready to help with your repair. Verified Local Experts Online now. Save Time & Money. Get Answers in Minutes.

Search results

  1. Loose the bolts 1 (4 units). Loose the lock nuts 3 of the bolts 2 (2 units). Tighten the bolts 2 alternately so as to keep the air end leveled until the belt presents the proper tension as per table 17.1. If the tension of the belt is correct, tighten bolts 1 and the lock nuts 3; otherwise, repeat the previous steps.

    • 7MB
    • 42
  2. • Power outlet must be compatible to the tool plug. To reduce the risk of shock, do not change the plug characteristics and do not use adapters. If required, replace the outlet with a plug suitable model. • Do not use your electric equipment in explosive atmo spheres (gas, fl ammable liquid or dust). The motor generate sparks that may

    • 3MB
    • 41
    • 2. INTRODUCTION
    • Warranty Term
    • Service Report
    • Questions
    • 3. COMPRESSOR INSPECTION
    • 4. APPLICATION
    • 5. SAFETY INSTRUCTION
    • 1. Location
    • Power factor correction
    • Local of installation
    • 12. START PROCEDURE
    • 1. PROCEDURES BEFORE BEGINNING MAINTENANCE
    • 2. PROCEDURES AFTER MAINTENANCE
    • 15. REMOVING MAINTENANCE PARTS - DISPOSAL
    • 16. CORRECTIVE MAINTENANCE
    • 1. Wastewater Disposal
    • 2. Draining of the Lubricant Oil from the Pump or Air/Oil Separator Tank
    • 3. Disposal of Solid Waste (large parts and product packaging)
    • The warranty will be granted to the compressor unit provided that:
    • WARRANTY GENERAL CONDITIONS
    • 20. SERVICE REPORT
    • Date Hours of operation Ambient temperature Compressor temperature Serviçes:

    FOR THE CORRECT USE OF THE PRODUCT, WE RECOMMEND THE COMPLETE READING OF THIS MANUAL. It will help you optimize the performance of the equipment, guarantee its safe operation and guide you through its preventive maintenance. In case you cannot solve a problem with the help of the information contained in this manual, contact the nearest SCHULZ AUTH...

    Familiarize with the Warranty Term; read carefully the compressor chapter “Warranty” at the end of this manual. In order to validate the Warranty and for more safety of the equipment, it is essential the use of genuine LUB SCHULZ SYNTHETIC or LUB SCHULZ oil for rotary screw compressor and genuine SCHULZ parts. The final user is responsible for the ...

    Any repair in the compressor should be carried out by SCHULZ AUTHORIZED SERVICE PROVIDER. After the repair or maintenance, fill out the service record supplied with this Manual.

    Whenever you have any questions about you rotary screw compressor, please, mention the model and serial number indicated on the plate fixed in the cabinet.

    Inspect and check if there were apparent damages caused by transportation. If so, inform the carrier immediately. Be sure that all damaged parts are replaced and that mechanic and electric problems are fixed before operating the air compressor.

    Schulz air compressors should only be used for atmospheric air compression up to the maximum pressure indicated in its identification plate.

    This equipment, if improperly used, can cause physical and material damage. To avoid these damages, follow the instructions below: This equipment may not be used by people with physical, sensorial, or mental handicaps. Or without experience or knowledge. People without the proper experience or knowledge may use this equipment only if properly super...

    Install the compressor in a covered area, well ventilated and free of dust, gases, toxic gases, chemical products humidity or any other kind of pollution. The noise level of the compressor, measured in an open space, may rise considerably if the installation place is surrounded by walls that reflect sound. This equipment must not be installed where...

    An economical and sensible way to obtain the reactive power necessary for the proper operation of your compressor is the installation of capacitors close to it. The installation of capacitors, however, must come after operational measures that lead to the decrease of need of reactive power, such as the turning off of motors or other idle or oversiz...

    Avoid the exposure to sunrays or closeness to equipment with high temperatures; Do not block the air inlet and outlet in the cabinets; The places should be protected against solid and liquid material in suspension (dust, oils); Avoid installation of capacitors near the roof (heat); Take care when installing the capacitors near non-linear loads.

    The compressors of the Line Compact are supplied from factory already tested and filled with mineral lubricant oil LUB SCHULZ or synthetic lubricant oil SH-46 SYNTHETIC (Kluber). IMPORTANT The Compressors are supplied from factory already tested and filled with synthetic lubricant oil LUB SCHULZ. Before the initial start of the compressor, check: t...

    ATTENTION There are hot surfaces inside the compressor cabinet after its stop. The use of Schulz genuine lubricant oil and parts extends the useful life of your compressor, preventing, thus, the loss of the Warranty of you compressor. Stop the compressor and make sure the tank has no pressure (wait for five minutes). Disconnect the compressor from ...

    Close the valve between the compressed air system and the compressor. Connect the compressor to the power supply (disconnecting switch) and make sure the compressor can be turned on without causing any accidents. Start the compressor.

    When service is over, the compressor oil, oil filter element and oil separator element must be disposed according to the local regulations. See further directions in “Environmental Orientations and Recommendations”.

    ATTENTION To guarantee the SAFETY and RELIABILITY of the product, the repairs, maintenance and adjustments must be performed through the nearest SCHULZ AUTHORIZED DEALER, which always uses genuine parts.

    The presence of liquid effluents or non-treated condensate from the tank or condensate separator in rivers, lakes or in other water receiving bodies may adversely affect the aquatic life and the water quality. The condensed daily withdrawn from the tank or condensate separator, according to Chapter Preventive Maintenance, must be kept in a containe...

    The disposal of lubricant oil from oil changes in the tank of the rotary screw compressor must comply with the requirements of the related local regulations.

    The creation of solid waste is one aspect that must be considered by the user in the use and the maintenance of the equipment. The impacts on the environment may cause significant changes in the quality of the soil, in surface and underground water, and in the population’s health due to improper disposal of the discarded residues (on streets, water...

    Periodicity is observed for the exchange of lubricating oil (Air end), and given installation conditions as instructed in this manual. The lubricant oil used is oil for rotary screw air compressor recommended in this Manual (Air End), and the spare parts used are genuine SCHULZ parts. The compressor will not operate without the filters or being dam...

    The warranty period elapses from the purchase date of the product. Possible shutdown of the equipment, regardless of the reason, will not generate the right to compensation, repair, refund or return of any nature. Warranty reception will only be held by SCHULZ AUTHORIZED DEALER in view of presentation of the original invoice, preferably on behalf o...

    The objective of this record is to register all the services and maintenances performed in your compressor. The records will help you follow the routine procedures and services performed. Please, always have at hand the following information when requesting a service. Keep this record together with the compressor and fill it out carefully.

    (change of oil, change of filter e lement, retightening of Notes

    • 6MB
    • 32
  3. Feb 19, 2024 · In conclusion, mastering maintenance for your Schulz oil-free air compressor is all about regular filter checks, monitoring oil levels (if applicable), inspecting for leaks, checking for unusual noises, and scheduling regular maintenance. By following these tips, you can keep your compressor in top shape and enjoy reliable performance for years ...

    • Matt Rocha
  4. This document is an instruction manual for alternative piston compressors produced by SCHULZ. It contains information about safety symbols, equipment inspection, applications, safety instructions, installation, startup procedures, preventative maintenance, corrective maintenance, environmental recommendations, failure diagnostics, warranty terms, and authorized dealers. The manual provides ...

  5. Spare Parts. Ensure the efficiency, reliability and saving of your equipment with the acquisition of original spare parts Schulz. The genuine parts, accessories and models are designed for perfect fits which will maintain the originality and performance of your equipment. The items Schulz prolong the useful life and ensure safety in the ...

  6. People also ask

  7. Schulz of America | Air Compressors, Air Treatment, Lubricants and Spare Parts. (770) 529-4731.

  1. People also search for