Funktion. SE-B*: Signal Evaluation – Basic Stan dard-Schutzgeräte für alle BITZER Hubkolben-Ver dich ter. Es überwacht die Druckgas- und Motortemperatur. Das SE-B* verriegelt sofort, wenn die voreingestellte Druck gas- oder Motortemperatur überschritten wird.
- 192KB
- 8
Page 4Technical manual SE-B1, SE-B2, SE-B3, SE-B42. General3. DefinitionsThe protection devices SE-B1, SE-B2, SE-B3 and SE-B4. Product rangeHereafter SE-Bxare used for protection of the motoragainst overheating by monitoring motor temperature bymeans of PTC-sensors mounted in the motors windings. Further, other temperatures can be monitored by ...
Reciprocating compressor with frequency inverter (with integrated STO) and protection device SE-B*.
Introduction. Electronic protection devices monitor the principal oper-ating parameters and protect the compressor and the system against abnormal operating conditions. The protection devices SE-E* monitor the motor and dis-charge gas temperature, rotation direction and phase failure.
- 317KB
- 36
All Bitzer reciprocating and scroll compressors of the ESH7 and ESH9 series have as standard equip-ment the motor protection devices SE-B1, SE-B2 or SE-B3 (Signal Evaluation - Basic). Protection modules for scroll and reciprocating compressors. SE-B1/SE-B2/SE-B3
se-b1-b2-b3-b4_technical-manual_uk - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Manual do relé de proteção dos compressores Bitzer
Jan 30, 2024 · Since the beginning of the year, Bitzer’s Schkeuditz factory has been replacing the SE-B3 compressor protection devices in its C3 series semi-hermetic Ecoline reciprocating compressors with the new IQ module.